Sales Chat
Support Chat
Sales:
888.220.6700
Phone:
401.628.1600
Computer Room, Server, Network, Temperature, Environment Monitoring & Alerting with Room Alert, TemPageR & Device ManageR! Computer Room, Server, Network, Temperature, Environment Monitoring & Alerting with Room Alert, TemPageR & Device ManageR!
AVTECH Support
Support Tickets
Submit Ticket
Lookup Ticket
Knowledge Base
FAQs
Application Notes
Technical Articles
Release Notes
Support Resources
Email-To-SMS Database
SNPP Database
TAP Dialup Database
Documentation
AVTECH ProductsCurrent Firmware & Software v5.7.2Device ManageR (Win)Released: May 7, 2013 v2.2.2Room Alert 32W
 (Includes Room Alert 32E)
Released: April 3, 2013
v3.5.1Room Alert 26W
 (Includes Room Alert 26WO) *
Released: September 14, 2011
v4.0.1Room Alert 24EReleased: March 9, 2012 v1.0.1Room Alert 12EReleased: April 19, 2013 v4.0.0Room Alert 11E *Released: April 27, 2012 v4.5.0Room Alert 7E *Released: April 3, 2012 v3.0.1Room Alert 4E
 (Includes Signal Towers)
Released: April 10, 2013
v1.1.1Room Alert 3EReleased: January 16, 2013 v4.5.0TemPageR 4E *Released: April 3, 2012 v3.0.1TemPageR 3EReleased: April 10, 2013 v4.1.0Device Discovery (Linux)Released: October 16, 2012 v4.1.0Device Discovery (Win)Released: October 16, 2012 Click Product Name To Download * This model no longer manufactured although fully supported by AVTECH.

AVTECH Support

Product: Room Alert 4E (Includes Signal Towers)
Article: Release Notes
Limit: All
View All Room Alert 4E (Includes Signal Towers) Release Notes View All Release Notes
January 13, 2011

Room Alert 4E Firmware v2.1.3 AvailableRoom Alert 4E Firmware v2.1.3 Released 13 January 2011

AVTECH Software is pleased to announce that an update to the Room Alert 4E Firmware is available for download at AVTECH.com.

Room Alert 4E Firmware v2.1.3 includes the following:


  • Added the ability to query the currently configured sensor labels via SNMP. Please be sure to download the latest SNMP MIB file for the Room Alert 4E to enable this new functionality.
  • Resolved an issue that could cause configured Pings to incorrectly report their status.
  • Resolved an issue that could cause the Switch Sensor Label to not save properly.
  • Resolved an issue that could cause temperature readings between 0.0C and -1.0C to display incorrectly on the web interface. They were being calculated properly for alert monitoring, but were being rounded incorrectly when displayed on the Status page.
  • For additional information about the updates included with Room Alert 4E v2.0.0 firmware, please click here.




Thank you for choosing Room Alert 4E and feel free to contact us at Support@AVTECH.com or 888.220.6700 if you have any questions.