Support

Knowledge Base  /  Frequently Asked Questions  /  Room Alert Manager

What Data Gets Included In Room Alert Manager’s Usage Statistics

Usage statistics help AVTECH make informed decisions regarding the development of Room Alert Manager’s most popular features and applications.

As of version 1.10, Room Alert Manager can optionally be configured to automatically send anonymous usage statistics to AVTECH. No sensitive information is included in the usage statistics, which are sent periodically at random times.

For information about what data gets included in Room Alert Manager’s usage statistics, or how to turn this feature on or off, please see the tabs below.

What data gets included in the usage statistics

The usage statistics that Room Alert Manager sends to AVTECH include non-identifiable data about alert configurations, report configurations and more.

They do not contain potentially-sensitive information, such as MAC addresses, IP Addresses, Alert Names, Device Names, User Names, Passwords, Email Addresses, Phone Numbers, etc.

Below are examples of usage statistics sent from Room Alert Manager:

  • system & applicationProperties
    • The system usage statistics include information such as the host operating system, its quantity of NICs, its quantity of cores, and its memory.
    • The applicationProperties usage statistics show whether the software is configured to use the default (main) database or an external database.
  • mailSettings
    • The mailSettings usage statistics include information such as the mail server port, whether or not authentication is enabled, and whether or not a backup mail server is configured.
    • These usage statistics do not include the mail server’s hostname, the sender Email address, or authentication credentials.
  • discoverySettings & pullSettings
    • The discoverySettings & pullSettings usage statistics include information such as the discovery interval, whether automatic discovery is enabled, the quantity of IP or NICs that have been excluded, and the quantity of manually-discovered devices.
    • These usage statistics do not include any IP addresses.
  • firmwareUpdateSettings
    • The firmwareUpdateSettings usage statistics show whether or not the software is configured to automatically get the latest firmware files from RoomAlert.com.
  • alerts
    • The alerts usage statistics include information such as the threshold, the channel type, the duration, the repeat interval, and whether or not the escalations are associated with a custom template.
    • These usage statistics do not include alert names, MAC addresses, device names, or the contents of custom notification templates.
  • schedules
    • The schedules usage statistics include information such as the weekday and start and end times.
  • users
    • The users usage statistics include information such as the user type (admin, manager or viewer), the user’s temperature scale, and whether or not multi-factor authentication has been enabled.
    • These usage statistics do not include the username, password, email address, or first & last name.
  • deviceGroups
    • The deviceGroups usage statistics include information such as the quantity of groups and the quantity of devices per group.
  • inventoryDevices
    • The inventoryDevices usage statistics include information about each discovered device, such as the device type, firmware version, and discovery source.
    • These usage statistics do not include the MAC address, device name, or IP address.
  • pingDevices
    • The pingDevices usage statistics include information such as the ping type (ICMP or HTTP), port, and timeout version.
    • These usage statistics do not include the ping name, IP address, host or path.
  • recipientGroups
    • The recipientGroups usage statistics include information such as the quantity of recipients and recipient type (email, text message, in-app message).
    • These usage statistics do not include email addresses or phone numbers.
  • reports
    • The reports usage statistics include information such as the report date range, and quantity and types of channels.
  • cellModemSettings
    • The cellModemSettings usage statistics include information such as whether or not the modem is using default settings.
    • These usage statistics do not include the COM port or service center number.
  • pushSettings
    • The pushSettings usage statistics include the missed push threshold.
  • relayConfigurations
    • The relayConfigurations usage statistics include information such as the relay or light tower’s trigger & clear configurations.
  • axisDevices
    • The axisDevices usage statistics include information about each discovered camera, such as the model, firmware version, and minimum interval between image captures.
    • These usage statistics do not include the camera’s MAC address or IP address.
How to enable/disable sending usage statistics

Sending usage statistics to AVTECH is a feature that can be turned on or off during the installation process (from within Room Alert Manager’s installer) or afterwards (from within its installation directory).

Select the tabs below for instructions.

During installationAfter installation

When you install Room Alert Manager v1.10+ (either as a new installation or as an update to a previous installation), you’ll see the following window in the installer.

  • Keep the checkbox in the window enabled if you’d like to allow Room Alert Manager to send usage statistics.
  • Un-check the box to prevent Room Alert Manager from sending usage statistics.

After installing Room Alert Manager, you can change this setting at any point by following these instructions.

These instructions require you to start and stop the Room Alert Manager service. This FAQ shows you how: How To Stop, Start And Restart The Room Alert Manager Service.

  1. Stop the Room Alert Manager service.
  2. Navigate to Room Alert Manager’s installation folder on its host system.
    • By default, it’s at C:\Program Files\AVTECH Room Alert Manager.
  3. Locate the “config” folder and open it.
  4. In the “config” folder, locate the “application.properties” file.
  5. Open that file in any text editor, such as Notepad or Notepad++.
  6. Locate the line that reads “avtech.usagestatistics.enabled”
    • Set this line to true to allow Room Alert Manager to send usage statistics.
    • Set this line to false to prevent Room Alert Manager from sending usage statistics.
  7. When you’re done making changes, save the “application.properties” file.
  8. You may now close Room Alert Manager’s installation folder.
  9. Then start the Room Alert Manager service.
Facebooktwitterredditpinterestlinkedinmail
Room Alert is Made in the USA, ships worldwide from our locations in the US and EU, and has been protecting facilities since 1988.

You may find Windows Command Prompt at the following path:

  • Windows 7 & 8
    Start--> All Programs--> Accessories--> Command Prompt
  • Windows 10
    Start--> All Apps--> Windows System--> Command Prompt

To run Windows Command Prompt as an administrator:

  • Windows 7 & 8
    Right-click on Command Prompt and select Run as administrator.
  • Windows 10
    Right-click on Command Prompt, select More and then select Run as administrator.

Example Polling Method Properties saved in Orion SolarWinds:

If you are using this client, you should configure the general SNMPv3 Credentials, but leave the Read / Write SNMPv3 Credentials section blank.

Room Alert Link- Supported Firmware Updates



Current S modelsCurrent E models
Room Alert 32SRoom Alert 32E
Room Alert 12SRoom Alert 12E
Room Alert 4E
Room Alert 3E

Room Alert Manager - Compatible Devices

The latest version of Room Alert Manager supports only the devices below.

It does not support any legacy Room Alert or TemPageR models.

Current S modelsCurrent E models
Room Alert 32SRoom Alert 32E
Room Alert 12SRoom Alert 12E
Room Alert 3SRoom Alert 4E
Room Alert 3E
Room Alert 3W